Here’s a practical way to set up sample tracking software for plates and barcodes in a multi-user synthetic biology lab.
1) Start with the workflow, not the software
Before choosing software, map the exact objects and events you need to track.
Typical entities in a synbio lab:
- Samples: strains, plasmids, DNA parts, oligos, cell pellets
- Containers: tubes, 96/384-well plates, racks, boxes
- Locations: freezers, shelves, incubators, plate positions
- Processes: transformation, plating, colony picking, PCR, assembly, sequencing, glycerol stock creation
- Users: who created, moved, used, or consumed a sample
Key question:
- Do you need to track only samples, or also plate maps, well contents, and sample lineage?
For a multi-user lab, you usually want:
- Unique ID for every sample/container
- Plate/well-level tracking
- Chain of custody
- Audit trail of changes
- Searchable metadata
- Permissions by user/group
2) Decide on the tracking model
Most labs use one of these models:
A. Container-centric
Each physical item gets a barcode:
- Tube barcode
- Plate barcode
- Box barcode
The software stores:
- What’s in it
- Where it is
- Who last touched it
Best for:
- Inventory-heavy labs
- Freezer organization
- Simple workflows
B. Sample-centric with derived containers
A sample has a stable ID, and each transfer into a plate/tube creates a new container record.
Best for:
- Lineage tracking
- Synbio workflows with many derivatives
- Plate-based screening
For synthetic biology, sample-centric plus container records is usually the best balance.
3) Define your barcode strategy
You’ll want a clear barcode convention from day one.
Recommended:
- Use one barcode per physical object
- Never reuse barcodes
- Separate barcode namespaces for:
- Samples
- Plates
- Boxes/racks
- Reagents if needed
Good barcode practices:
- Use 2D barcodes on plates/tubes if possible
- Link barcode to internal ID in the database
- Print human-readable text next to barcode
- Keep barcode format fixed and machine-scannable
Example ID scheme:
SMP-000123for samplesPLT-000456for platesBOX-000078for storage boxes
If using 2D barcodes:
- Datamatrix is common for small tubes
- QR can work, but Datamatrix is often better for lab hardware
4) Choose software based on lab size and complexity
Options:
Commercial LIMS
Best if you need:
- Built-in compliance
- Permissions
- Audit trails
- Vendor support
Examples:
- Benchling
- LabWare
- SciCord
- LabVantage
Open-source / self-hosted tools
Best if you want:
- Lower cost
- More customization
- Internal hosting
Examples:
- openBIS
- eLabFTW
- Bika LIMS / Senaite
- custom Django/Flask app
Hybrid approach
Many synbio labs use:
- An ELN for notes/protocols
- A LIMS/inventory system for samples and plates
- Automation scripts for barcode printing/scanning
If you need multi-user plate tracking, prioritize:
- Plate map support
- Barcode generation/scanning
- Permissions
- API access
- Audit logs
5) Design the database structure
At minimum, create tables/objects for:
Core tables
- Users
- Projects
- Samples
- Containers
- Plates
- Well contents
- Locations
- Events / Transactions
- Barcodes
Important relationships
- A sample can exist in multiple containers over time
- A plate has many wells
- A well can contain one or more sample records, depending on your workflow
- A sample may be derived from another sample
- Every movement or action should create an event record
Example event types:
- Created
- Aliquoted
- Moved
- Scanned
- Updated
- Used in experiment
- Discarded
- Archived
This gives you traceability and helps resolve conflicts when multiple users work on the same items.
6) Build in permissions and ownership
In a multi-user lab, this is critical.
Suggested permission model:
- Admin: manage schemas, users, global settings
- Manager/PI: view all lab records, approve changes
- Standard user: create/edit items in their projects
- Read-only: view inventory, no edits
Additional rules:
- Sample ownership by project/team
- Locked records for critical steps
- Require sign-off for destruction or transfer
- Track who changed what and when
7) Standardize plate maps and well conventions
Plate tracking fails when people use inconsistent naming.
Define:
- Plate format: 96-well, 384-well, etc.
- Well labels: A1–H12, etc.
- Orientation: always define A1 location and scanning orientation
- Fill direction: row-major or column-major
- Reserved wells: controls, blanks, references
Store plate maps as structured data:
- Plate ID
- Well ID
- Contents
- Volume
- Concentration
- Status
If you do pooled libraries or screening:
- Support multiple sample types per plate
- Support dilution series
- Track replicates and controls explicitly
8) Set up barcode hardware and labeling
You’ll need reliable printing and scanning.
Hardware
- Label printer: Zebra is common
- Scanner: handheld 2D scanner or camera-based scanning
- Optional: plate reader or automated handlers with barcode support
Labeling rules
- Labels must survive:
- -80°C storage
- liquid nitrogen if needed
- ethanol/water exposure
- centrifugation and handling
Best practices
- Validate label stock for your freezer conditions
- Print in a consistent size and placement
- Use redundant labeling:
- barcode
- human-readable ID
- maybe project code
9) Create SOPs for every sample action
Software alone won’t solve tracking unless everyone follows the same procedure.
Write SOPs for:
- Receiving or creating a new sample
- Printing and assigning barcode
- Aliquoting into plates
- Scanning on transfer
- Moving plates between storage locations
- Updating inventory after use
- Discarding or archiving samples
A simple rule:
- No unlabeled container may enter the workflow
- Every transfer requires a scan or logged action
10) Integrate with your workflows
For synthetic biology labs, connect tracking to:
- DNA design tools
- Sequencing data
- Automation scripts
- Liquid handlers
- Colony pickers
- Plate readers
Useful integrations:
- API to create plate maps automatically from design files
- Import/export CSV for legacy workflows
- Barcode scanning at each workbench
- Auto-generation of worklists for liquid handling
If you have automation, barcodes should be readable by both humans and machines.
11) Add validation and quality control
To avoid tracking drift:
- Periodically reconcile physical inventory vs database
- Run barcode scans of freezer boxes
- Check for duplicate IDs
- Flag orphaned samples
- Audit plate contents after major workflows
Suggested QC checks:
- Plate exists but no location assigned
- Well contents missing
- Sample has no owner/project
- Barcode scanned but not registered
- Duplicate barcode detected
12) Plan migration from spreadsheets
If you’re starting from spreadsheets:
- Freeze the old process
- Clean and standardize IDs
- Import into the new system
- Validate a subset manually
- Train users
- Switch new samples to the system
- Archive old records read-only
Don’t try to “perfectly import everything” before going live. Start with current inventory and active projects.
13) Train the lab
Adoption is the hardest part.
Train on:
- How to create a sample
- How to print and attach labels
- How to scan during transfers
- How to find a sample
- What to do if a barcode is damaged
- How to correct mistakes
Make the workflow easy:
- Few clicks
- Default fields prefilled
- Mobile-friendly or scanner-friendly UI
- Search by barcode, sample name, project, or location
14) Recommended minimum viable setup
If you want something practical and not overbuilt, start with:
- A sample database with unique IDs
- Plate and well tracking
- Barcode generation and printing
- Scanner-based check-in/check-out
- Location tracking
- Audit log
- User accounts and permissions
- CSV import/export
- Basic API
That’s enough to support a serious multi-user synbio lab.
15) Common pitfalls to avoid
- Using human-readable names as the primary key
- Reusing barcodes
- Letting users edit IDs manually
- Not tracking plate orientation
- No audit trail
- No permissions
- Allowing “free text” instead of controlled fields
- Not defining SOPs for transfers
- Ignoring freezer/location tracking
- Overcomplicating the first version